New Schneider LRE359 EasyPact TVS differential thermal overload relay
New Schneider LRE359 EasyPact TVS differential thermal overload relay

New Schneider LRE359 EasyPact TVS differential thermal overload relay

MOQ : 1 Piece

New Schneider LRE359 EasyPact TVS differential thermal overload relay Specification

  • Usage
  • Standard
  • Material
  • Standard
  • Temperature
  • -2060 C Celsius (oC)
  • Height
  • 54 mm Millimeter (mm)
  • Product Type
  • Differential thermal overload relay
  • Voltage
  • 690 V AC Volt (v)
  • Color
  • Standard
  • Warranty
  • 1 Year
  • Width
  • 70 mm Millimeter (mm)
  • Length
  • 113 mm Millimeter (mm)
 

New Schneider LRE359 EasyPact TVS differential thermal overload relay Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Telegraphic Transfer (T/T)
  • Delivery Time
  • 5 Days
  • Packaging Details
  • Standard
  • Main Export Market(s)
  • Asia
  • Main Domestic Market
  • Gujarat
 

About New Schneider LRE359 EasyPact TVS differential thermal overload relay


The LRE relay is a differential thermal overload relays for use with fuses or magnetic circuit-breakers GV2 L and GV3 L. Its thermal setting range is 48-65A 50/60Hz and the tripping class is 10A conforming to IEC 60947-4-1. It can be direct mounted on EasyPact TVS contactors with screw clamp terminals connection. It protects unbalanced loads and motors with 30kW at 400VAC. It provides manual or automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach).



Reliable Motor Protection

The LRE359 EasyPact TVS differential thermal overload relay safeguards motors from overload conditions, ensuring longevity and operational stability. The device detects thermal overloads and interrupts power, effectively protecting equipment from damage due to excessive current. Its advanced design is aligned with Schneider Electric's renowned standards, making it a trusted component in electrical panels.


Versatile Applications and Easy Installation

Engineered for standard usage in diverse environments, this relay fits seamlessly into a variety of motor control circuits. Its compact size (113 mm x 70 mm x 54 mm) allows for straightforward integration. The device operates within a broad temperature range, making it suitable for both indoor and outdoor installations. Multiple distribution channels in India ensure widespread availability and reliable after-sales service.

FAQ's of New Schneider LRE359 EasyPact TVS differential thermal overload relay:


Q: How does the Schneider LRE359 EasyPact TVS differential thermal overload relay work?

A: This relay functions by monitoring the temperature caused by motor overloads. When excessive current passes through a motor, causing it to overheat, the relay detects the rise in temperature and disconnects the circuit, thus preventing equipment damage.

Q: What are the main benefits of using this overload relay?

A: The relay provides dependable protection against motor overload, minimizing downtime and repair costs. Its compact design, wide temperature operating range, and compliance with industry standards make it suitable for a variety of industrial applications.

Q: When should I use the LRE359 overload relay in my setup?

A: You should install this relay whenever you need to protect AC motors operating up to 690 V against thermal overloads, especially in industrial environments where reliable motor protection is critical.

Q: Where can I purchase or source the Schneider LRE359 relay in India?

A: The LRE359 relay is available through authorized dealers, distributors, exporters, suppliers, and other channel partners such as retailers and wholesalers throughout India.

Q: What is the installation process for this thermal overload relay?

A: Installation involves fixing the relay onto your motor control circuit in accordance with the manufacturer's guidelines. Ensure proper wiring and calibration to match the motor's current rating for effective protection.

Q: How can I ensure the relay performs optimally during operation?

A: To maintain optimal performance, install the relay within its specified temperature range (-20C to 60C) and ensure regular inspections. Adhering to standard usage and maintenance protocols will help maximize its lifespan and effectiveness.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Contactors and Protection Relays Category

New Schneider Electric TeSys F- mechanical interlock - for 2 horizontal contactors

New Schneider Electric TeSys F- mechanical interlock - for 2 horizontal contactors

Minimum Order Quantity : 1 Piece

Product Type : Mechanical interlock

Voltage : Not applicable (mechanical accessory)

Weight : Approx. 0.15 kg

Temperature : Operating: 25C to +55C

Warranty : 1 Year

New Schneider LADN11 Auxiliary contact block

New Schneider LADN11 Auxiliary contact block

Minimum Order Quantity : 1 Piece

Product Type : Auxiliary contact block

Voltage : 690 V AC Volt (v)

Temperature : 6080 C Celsius (oC)

Warranty : 1 Year

New Schneider LC1E0910M7  EasyPact TVS contactor

New Schneider LC1E0910M7 EasyPact TVS contactor

Minimum Order Quantity : 1 Piece

Product Type : Contactor

Voltage : 220 V AC Volt (v)

Weight : 0.3 kg Kilograms (kg)

Warranty : 1 Year

New Schneider SR3B261BD modular smart relay

New Schneider SR3B261BD modular smart relay

Minimum Order Quantity : 1 Piece

Product Type : Modular smart relay

Voltage : 24 V Volt (v)

Weight : 0.4 kg Kilograms (kg)

Temperature : 4070 C Celsius (oC)